3Com 7757 Configuration Manual page 179

3com switch 7750 family
Hide thumbs Also See for 7757:
Table of Contents

Advertisement

Setting Speedup for a
Port
c
Controlling UP/Down
Log Output on a Port
n
Last 100 seconds input:
Last 100 seconds output:
Table 115 Set the interval to perform statistical analysis on port traffic
Operation
Enter system view
Enter Ethernet port view
Set the interval to perform
statistical analysis on port
traffic
Perform the following configuration to speed up the hardware in a port or out of
a port.
Table 116 Set speedup for a port
Operation
Enter system view
Enable the hardware speedup
function inside the port
Disable the hardware speedup
function inside the port
Enable the hardware speedup
function outside the port
Disable the hardware speedup
function outside the port
CAUTION:
The hardspeedup enable/disable commands are applicable to type-A I/O
Modules only, including 3C16860, 3C16861, LS81FS24A, 3C16858, and
3C16859.
The speedup enable/disable commands are applicable to non-type-A I/O
Modules only.
The commands above are diagnostic, so you cannot use them at discretion.
An Ethernet port has two physical link statuses: UP and Down. When the state of
an Ethernet port changes, the switch will send log information to the log server,
which then responds accordingly. If the status of Ethernet ports changes
frequently, the switch will send log information to the log server frequently,
burdening the log server and consuming plenty of network resources.
To solve the problem, you can use the Up/Down log information output control
function. By using the function, you can choose to monitor certain Ethernet ports
instead of monitoring all ports, so as to reduce the quantity of log information
output to the log server.
After you allow a port to output the Up/Down log information, if the physical link
status of the port does not change, the switch does not send log information to
the log server but monitors the port in real time.
Ethernet Port Configuration
0 packets/sec 0 bytes/sec
0 packets/sec 0 bytes/sec
Command
system-view
interface interface-type
interface-number
flow-interval interval
Command
system-view
hardspeedup enable
hardspeedup disable
speedup enable
speedup disable
179
Description
-
-
Optional
By default, this interval is 300
seconds.
Description
-
Optional
By default, the hardware
speedup function inside the
port is enabled.
Optional
By default, the hardware
speedup function outside the
port is enabled.

Advertisement

Table of Contents
loading

This manual is also suitable for:

775077587754

Table of Contents