Aborting Test Patterns - Paradyne 3150 Operator's Manual

Zhone 3150 csu: operators guide
Hide thumbs Also See for 3150:
Table of Contents

Advertisement

8. Testing

Aborting Test Patterns

Use the Abort command to stop all test patterns or any selected test pattern active
on the CSU.
Procedure
To abort test patterns:
8-14
1. From the top-level menu screen, select Test.
2. From the Test screen, select Ptrns.
Test:
Rlpbk
Lpbk
F2
F1
3. From the Patterns screen, select Abort.
Patterns:
Abort
Send
F2
F1
4. From the Patterns Abort screen, press the desired Function key to abort either
All active test patterns, active Send test patterns, or the active Monitor (Mon)
test pattern.
Patterns: Abort
All
Send
F2
F1
The CSU terminates the selected test pattern and displays the message
Command Complete.
NOTE:
If you mistakenly choose to abort a test pattern that is not currently running, a
Command Complete message still displays and the test pattern currently
active still runs. Use the TStat branch to view the test status to determine if the
abort was successful.