  • Page 1 ACCULINK 3151 CSU QUICK REFERENCE Document No. 3151-A2-GL11-50...
  • Page 2: Document Feedback

    Copyright 1998 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Ave.
  • Page 3: Quick Reference

    ACCULINK 3151 CSU Quick Reference Document Number 3151-A2-GL11-50 November 1998 Product Documentation on the World Wide Web We provide complete product documentation online. This lets you search the documentation for specific topics and print only what you need, reducing the waste of surplus printing.
  • Page 4: Quick Start Procedure

    Quick Start Procedure The following procedure is for experienced CSU users who are familiar with the 3151 CSU installation process and have no special requirements for their application. See the ACCULINK 315x Channel Service Unit Operator’s Guide for more information.
  • Page 5 2. Attach the DTE cable (DB15) to the appropriate DTE connector on the Auxiliary Backplane. (See the COMSPHERE 3000 Series Carrier Installation Manual (3000-A2-GA31) for detailed cable and connector information.) Connect the other end of the DTE cable to the customer premises equipment. 3.
  • Page 6 5. Insert the CSU circuit card into the appropriate slot in the carrier. The power-up self-test begins. 6. If you intend to use front panel emulation, connect the cable from the PC to Port 2 on the Auxiliary Backplane using the COM port adapter and COM-port-to-PC cable. 7.
  • Page 7: Configuration Options

    Configuration Options Configuration options are accessed from the Cnfig branch of the front panel menu. CSU ESF Stat Test Cnfig Ctrl...
  • Page 8 Factory default configuration options are shown in boldface type in the following tables. Table 1. DTE Interface Configuration Options Option Factory 1 DTE Framing: DTE Framing: DTE Coding: DTE Coding: B8ZS 0–133 133–266 Equal: Equal: 266–399 (DTE Line (DTE Line Equalizer) 399–533 533–655...
  • Page 9 Table 2. Network Interface Configuration Options (2 of 2) Option Factory 1 Enab NET LLB: NET LLB: Disab Enab NET PLB: NET PLB: Disab BitStuff: BitStuff: One (Framed All Ones) KeepAlive: KeepAlive: NetLp (Loopback of network signal) Enab Yellow: Yellow: Disab Edit Circuit Ident:...
  • Page 10 Table 4. User Interface Configuration Options (1 of 3) Option Factory 1 Enab Self-Test: Self-Test: Disab Enab Dial-In: Dial-In: Disab None Password: Password: Modem Both Enab Com Port: Com Port: Disab Mgmt ASCII Com Use: Term Disab ComExtDev: Other Edit ComConnPrefix: ComConnPrefix: Clear...
  • Page 11 Table 4. User Interface Configuration Options (2 of 3) Option Factory 1 Com Rate: (Communication Port (Communication Port Rate) Rate) 14.4 19.2 Char Length: Char Length: None CParity: CParity: Even (Communication Port Parity) Parity) CStop Bits: CStop Bits: (Communication Port (Communication Port Stop Bits) Bit )
  • Page 12 Table 4. User Interface Configuration Options (3 of 3) Option Factory 1 TnDiscTm: (Telnet TnDiscTm: (Telnet Disconnect Time) t Ti Down Save Table 5. Alarm Configuration Options Option Factory 1 Disab Alrm Msg: Alrm Msg: Enab SNMP Trap: SNMP Trap: Disab Enab TrapDisc:...
  • Page 13 Table 6. General Management Configuration Options (1 of 2) Option Factory 1 Disab SNMP Mgt: SNMP Mgt: Enab Disab NMS Valid: NMS Valid: Enab Num Sec Mgrs: Num Sec Mgrs: 2–10 Edit NMS n IP Adr: NMS n IP Adr: Clear Read NMS n Access:...
  • Page 14 Table 6. General Management Configuration Options (2 of 2) Option Factory 1 Edit Com NetMask: Com NetMask: Clear Com Link: Com Link: SLIP Enable IPBusMast: IPBusMast: Disab None IPBus Def Netwk: Def Netwk: Factory 2 Comments/Description Edit The Subnet Mask needed to access the device when the COM access the device when the COM Clear...
  • Page 15 Table 7. Management Trap Configuration Options Option Factory 1 Num Trap Mgrs: 2–6 Edit Trap n IP Adr: Trap n IP Adr: Clear None IPBus Trap n Dst: Trap n Dst: Disab Warm Gen Trap: Gen Trap: Auth Both Enab Entp Trap: Entp Trap: Disab...
  • Page 16: Important Safety Instructions

    Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. When an ac power source is used, this product is intended to be used with a three-wire grounding type plug — a plug which has a grounding pin. This is a safety feature.
  • Page 17: Emi Warnings

    11. In addition, if the equipment is to be used with telecommunications circuits, take the following precautions: — Never install telephone wiring during a lightning storm. — Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. —...
  • Page 18 1. This equipment complies with Part 68 of the FCC rules. On the equipment is a label that contains, among other information, the FCC registration number for this equipment. The label is located on the 3151 CSU’s circuit card. If requested, this information must be provided to the telephone company.
  • Page 19 — Via the Internet: Visit the Paradyne World Wide Web site at http://www.paradyne.com — Via Telephone: Call our automated call system to receive current information via fax or to speak with a company representative. Within the U.S.A., call 1-800-870-2221 Outside the U.S.A., call 1-727-530-2340 If the trouble is causing harm to the telephone network, the telephone company may request that you remove the equipment from the network until the problem is resolved.

This manual is also suitable for:

Acculink 3151 csu