C. Configuration Options
Table C-7. Management Trap Configuration Options (2 of 3)
C-28
Gen Trap: Both
Next
Disab
Warm
Auth
General Trap Types. Specifies the general trap types to enable.
–
Disab
Disables the sending of trap messages for warmStart and authenticationFailure
events.
–
Warm
Sends trap messages for warmStart events to the currently configured trap
manager(s).
–
Auth
Sends trap messages for authenticationFailure events to the currently configured
trap manager(s).
–
Both
Sends trap messages for warmStart and authenticationFailure events to the
currently configured trap manager(s).
NOTE: This configuration option is not available if the SNMP Trap configuration option
(see
Table C-5, Alarm Configuration
Entp Trap: Enab
Next
Enab
Disab
Prev
Enterprise Specific Traps. Specifies whether enterpriseSpecific traps are enabled.
–
Enab
Sends trap messages for enterpriseSpecific events to the currently configured
trap manager(s).
–
Disab
Disables the sending of trap messages for enterpriseSpecific events.
NOTE: This configuration option is not available if the SNMP Trap configuration option
(see
Table C-5, Alarm Configuration
Link Trap: Both
Next
Disab
Up
Down
Link Trap Type. Specifies the link trap type to enable. Interfaces monitored for linkUp and
linkDown traps are specified with the Trap I/F configuration option.
–
Disab
Disables the sending of trap messages for linkDown or linkUp events.
–
Up
Sends trap messages for linkUp events to the currently configured trap manager(s).
–
Down
Sends trap messages for linkDown events to the currently configured trap
manager(s).
–
Both
Sends trap messages for linkUp and linkDown events to the currently configured
trap manager(s).
NOTE: This configuration option is not available if the SNMP Trap configuration option
(see
Table C-5, Alarm Configuration
March 2001
Both
Prev
Options) is disabled.
Options) is disabled.
Both
Prev
Options) is disabled.
3150-A2-GB24-10