Aborting Loopbacks - Paradyne 3150 Operator's Manual

Zhone 3150 csu: operators guide
Hide thumbs Also See for 3150:
Table of Contents

Advertisement

Aborting Loopbacks

The Abort Loopback command stops all loopback tests or any selected loopback
test currently active on the CSU.
Procedure
To abort one or more loopback tests:
3150-A2-GB24-10
1. From the top-level menu screen, select Test.
2. From the Test screen, select Lpbk.
Test:
Rlpbk
Lpbk
F2
F1
3. From the Loopback screen, select Abort.
Loopback:
Abort
LLB
F2
F1
4. From the Loopback Abort screen, press the desired Function key to abort All
or one specific loopback test. Use the scroll keys, if necessary.
Loopback: Abort
All
LLB
F2
F1
When abort is complete, the message Command Complete appears on the
Abort screen.
NOTE:
If you mistakenly choose to abort a loopback test that is not currently running,
a Command Complete message will still display and the loopback that is
currently active will still be running. Use the TStat branch to view the test
status to determine if the abort was successful.