Enabling The Communication Port For Carrier-Mounted Csus - Paradyne 3150 Operator's Manual

Zhone 3150 csu: operators guide
Hide thumbs Also See for 3150:
Table of Contents

Advertisement

4. Configuration

Enabling the Communication Port for Carrier-Mounted CSUs

Communication between the carrier-mounted CSUs and an external PC, ASCII
device, SNMP manager, or async terminal interface (attached either locally or
through an external modem) occurs through a shared communication (COM) port.
(For COM port cabling information, refer to the
Installation Manual
have a dedicated COM port for external access. Once the COM port is enabled,
other COM port configuration options can be selected. These options are used to
configure Port 2 on the Auxiliary Backplane as a COM port for the carrier.
Procedure
To enable the COM port on the carrier-mounted CSU:
4-22
.) Unlike standalone CSUs, the carrier-mounted CSUs do not
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied into the Edit area by using the
appropriate Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. Press the
key until User is displayed. Select User.
Edit:
NET
Gen
F2
F1
5. Press F1 (Next) until the COM Port configuration option appears.
6. Select Enab to enable the COM port for the carrier-mounted CSU.
Com Port:
Next
Enab
F2
F1
March 2001
COMSPHERE 3000 Series Carrier
User
F3
Disab
F3
3150-A2-GB24-10