Paradyne 3150 Operator's Manual page 90

Zhone 3150 csu: operators guide
Hide thumbs Also See for 3150:
Table of Contents

Advertisement

7. Monitoring and Troubleshooting
Performance Reports
When the network interface is configured for ESF operation, network performance
is continuously monitored and maintained in two sets of aggregate registers:
T
T
The User registers contain an extra status register (Status Event). Registers
shown on the front panel LCD are listed in
These registers are status registers that collect performance data for the previous
24-hour period. Performance data is updated in 15-minute intervals. After
15 minutes, the current interval is rolled over into a set of accumulator registers
that represent the previous 96 15-minute intervals for the register. An interval total
of how many of the 96 registers contain valid data is also kept, as well as a
24-hour total for each accumulator register.
Procedure
To display User Network Interface (User) performance:
7-6
Carrier Network Interface Registers (Telco)
User Network Interface Registers (User)
NOTE:
The following procedure is an example only. Screen displays may vary
depending on the model and configuration of the CSU. The procedure for
displaying Telco registers is similar to this example.
1. From the top-level menu screen, select Stat.
2. From the Status screen, select Perf.
Status:
DevHS
STest
F1
F2
3. Select User registers.
Performance:
Telco
User
F1
F2
March 2001
Table 7-3, Performance
Perf
F3
F3
Registers.
3150-A2-GB24-10