Specifying The Community Name(S) And Access Type(S) - Paradyne 3150 Operator's Manual

Zhone 3150 csu: operators guide
Hide thumbs Also See for 3150:
Table of Contents

Advertisement

Specifying the Community Name(s) and Access Type(s)

You have the capability of specifying up to two community names (community
name 1 and community name 2) to be used by external SNMP managers when
trying to access objects in the CSU's MIB. Once you specify the community
name(s), you must then specify the type of access to the MIB that SNMP
managers in the community are permitted to have.
Procedure
To specify the community name 1 and its access type:
3150-A2-GB24-10
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied into the Edit area by using the
appropriate Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the
the screen.
5. Select Mgmt.
Edit:
User
Alarm
F1
F2
6. From the Mgmt Config screen, select Gen.
Mgmt Config:
Gen
Trap
F1
F2
7. Press F1 (Next) until the CommunityName1 configuration option appears.
8. Press F2 (Edit) to edit the community name.
CommunityName1:
Next
Edit
F1
F2
March 2001
key until the Mgmt selection appears on
Mgmt
F3
F3
Clear
F3
4. Configuration
4-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

3151Acculink csu 3150-a4Acculink csu 3151