Monitoring Test Patterns

Use the Monitor command to monitor a QRSS test pattern on the network
interface.
This command provides the number of errors detected in the test pattern (5 digits,
maximum 99999).
Procedure
To monitor a QRSS test pattern:
3150-A2-GB24-10
The Test Started screen appears.
Send: Name
Test Started
F1
F2
If the CSU is already sending the test pattern you selected, the message
Already active appears. If you selected more than one test pattern, the
message Invld Test Combo appears.
1. From the top-level menu screen, select Test.
2. From the Test screen, select Ptrns.
Test:
Rlpbk
Lpbk
F2
F1
3. From the Patterns screen, select Mon.
Patterns:
Abort
Send
F2
F1
The Monitor screen appears with the error count. If the maximum of 99999 is
exceeded, OvrFlw appears instead of the count. If the receiver loses
synchronization while the monitor is active, No Sync appears.