Table C-7. Management Trap Configuration Options (3 of 3)
3150-A2-GB24-10
Trap I/F: Both
Next
NET
DTE
Both
Link Trap Interfaces. Specifies which interfaces generate linkUp and linkDown trap
messages. These traps are supported on the T1 interfaces (network and DTE).
NET
Sends trap messages for linkUp and linkDown events occurring on the network
interface.
DTE
Sends trap messages for linkUp and linkDown events occurring on the DTE
interface.
Both
Sends trap messages for linkUp and linkDown events occurring on both the
network and DTE interface.
NOTE: This configuration option is not available if the Link Trap configuration option is
not configured to generate trap messages for linkUp or linkDown events.