LEDs

There are twelve LEDs on the CSU front panel
LED indicates normal operation. A yellow LED indicates a warning. Conditions are
sampled every tenth of a second.
Figure 3-5.
The twelve front panel LEDs are grouped into three sections to indicate the status
of the:
T
T
T
Table 3-1.
3150-A2-GB24-10
CSU LEDs
System LEDs
(Table
3-1)
Network Interface LEDs
DTE Interface LEDs
(Table
System LEDs
Name
Color
Meaning
OK
Green
Indicates the current operational state of the CSU.
ON: The CSU is operational and has power.
OFF: The CSU is performing a power-on self-test or a system failure
has occurred.
BLINKING: A software download is in progress.
FAST BLINK: The carrier-mounted CSU is currently selected by the
SDCP.
FAIL
Yellow
Indicates a system failure or a self-test.
ON: A device error/fault is detected or a reset has just occurred.
OFF: No system failures are detected.
BLINKING : A self-test is in progress.
TEST
Yellow
A system test is in progress.
ON: A loopback or pattern test has been initiated either locally, by
the network, or externally.
OFF: No tests are active.