Advertisement

Table C-4. User Interface Configuration Options (3 of 10)
3150-A2-GB24-10
ComConnPrefix:
Next
Edit
Clear
Prev
Carrier Communication Port Connect Prefix. Specifies the connect prefix to the dial
directory phone number. When you make a connection or the CSU automatically makes a
connection (dial-out alarms or traps) through the communication port, the connect prefix
and the dial directory phone number are used to establish the connection. The connect
prefix is an ASCII text string and may be up to 20 characters in length. If the connect
prefix is NULL, then no connect prefix is used.
Edit
Allows you to edit and/or display the connect prefix using the generic text string
entry screen.
Clear
Allows you to clear the connect prefix. The connect prefix is set to a null string.
NOTES:
– This configuration option is available on carrier-mounted CSUs only.
– This configuration option is not available if the ComExtDev configuration option is
set to AT or the communication port is disabled.
CAUTION: If ComExtDev is configured for Other and the external device requires
characters after the dial phone number, you must append the characters to the phone
number.
ComConnected:
Next
Edit
Clear
Prev
Carrier Communication Port Connect Indication String. Specifies the communication
port's connect indication string. When you make a connection or the CSU automatically
makes a connection (dial-out alarms or traps) through the communication port, this string
determines that the connection has been established. The connect indication string is an
ASCII text string and may be up to 20 characters in length. If the connect indication string
is not received within 1 minute, it will time-out the connection. If the connect indication
string is NULL, the communication port's receive data stream is not searched and a
transition in the Carrier Detect (CD) lead is used to determine that a connection has been
established.
Edit
Allows you to edit and/or display the case-sensitive connect indication string using
the generic text string entry screen.
Clear
Allows you to clear the connect indication string. The connect indication string is
set to a null string.
NOTES:
– This configuration option is available on carrier-mounted CSUs only.
– This configuration option is not available if the ComExtDev configuration option is
set to AT or the communication port is disabled.
March 2001
C. Configuration Options
C-9