Paradyne 3150 Operator's Manual page 142

Zhone 3150 csu: operators guide
Hide thumbs Also See for 3150:
Table of Contents

Advertisement

C. Configuration Options
Table C-5. Alarm Configuration Options (4 of 4)
C-20
AlrmRelay: Disab
Next
Enab
Disab
Prev
Alarm Relay. Specifies whether an alarm condition for this circuit card activates the
shared alarm relay on the 3000 Series Carrier. The alarm deactivates if the condition(s)
causing it is corrected. An Alarm Cut-Off issued from the SDCP (or PC Emulation
program) for a particular carrier-mounted CSU also deactivates the alarm. The
carrier-mounted CSU does not reactivate the alarm relay until all alarm conditions for the
unit are cleared.
The following alarm conditions activate the alarm relay if this configuration option is
enabled:
T
Continuous Loss of Signal (LOS) or Out of Frame (OOF) at either the network or DTE
interface.
T
Alarm Indication Signal (AIS) received at either the network or 7DTE interface.
T
Yellow alarm signal received at either the network or DTE interface.
T
Excessive Error Rate (EER) detected at the network interface.
NOTE: This configuration option is available on carrier-mounted CSUs only.
March 2001
3150-A2-GB24-10

Advertisement

Table of Contents
loading

This manual is also suitable for:

3151Acculink csu 3150-a4Acculink csu 3151

Table of Contents