ACCULINK 315x CSU
Test Patterns
Use the Test Pattern commands to send, monitor, and
abort test patterns. Available test patterns are:
QRSS – A quasi-random signal source
approximating live data that can be monitored for
logic errors.
1-in-8 – A test pattern consisting of a one (1)
followed by seven zeros.
Sending Test Patterns
Use the Send command to start transmission of a test
pattern. Only one test pattern can be active at a time.
To send a test pattern,
1. From the top-level menu screen, select Test.
2. From the Test screen, select Ptrns.
Test:
Rlpbk Lpbk
F1
3. From the Patterns screen, select Send.
Patterns:
Abort
F1
4. From the Patterns Send screen, press F1 to send a
QRSS pattern or F2 to send a 1-in-8 pattern.
Patterns: Send
QRSS 1in8
F1
4-18
Ptrns
F3
F2
Send
Mon
F2
F3
F3
F2
February 1998
The Test Started screen appears.
Send: Name
Test Started
F1
If the CSU is already sending the test pattern you
selected, the message Already active appears. If
you selected more than one test pattern, the
message Invld Test Combo appears.
Monitoring Test Patterns
Use the Monitor command to monitor a QRSS test
pattern on the network interface.
This command provides the number of errors detected
in the test pattern (5 digits, maximum 99999).
To monitor a QRSS test pattern,
1. From the top-level menu screen, select Test.
2. From the Test screen, select Ptrns.
Test:
Rlpbk Lpbk
F1
3. From the Patterns screen, select Mon.
Patterns:
Abort
F1
The Monitor screen appears with the error count.
If the maximum of 99999 is exceeded, OvrFlw
appears instead of the count. If the receiver loses
synchronization while the monitor is active, No
Sync appears.
F2
F3
Ptrns
F2
F3
Send
Mon
F3
F2
3150-A2-GB21-80