Setting The Segment Parameters - Dürkopp Adler D887 e-con Operating Instructions Manual

Table of Contents

Advertisement

Programming Commander DELTA
Icon
Parameter
Seam Parameter
Stitch length
Needle thread tension
Sewing foot pressure
Differentiation
Type of differentiation
Seam segment length
or
Number of stitches in segment
Max. Speed
It is possible to reduce the maximum
sewing speed at this point. The maximum
sewing speed can be set in the software
at the Technician level.
Positioning of the needle
Position of the needle when sewing
stops.
Operating Instructions D887 e-con - 00.0 - 11/2023
5.9.7

Setting the Segment parameters

There are various options for setting the parameters in the segment.
The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
Settings
Value range
01.0 – 02.0 [mm]
(depending on the sewing
equipment and the subclass)
Value range
01 – 99 [%]
Value range
01 – 20
Value range
-06 – 16
Value range
Upper/lower
You can set the active option at
the Technician level Machine
configuration > Seam segment mode.
The s.p.m. option is set at the
factory. The display remains after
the thread has been cut, while
counting/measuring will begin
when sewing starts again.
Value range
0150 – 2500 [rpm]
(depending on subclass)
Value range
On/Off
153