Code
Type
2352
Error
2371
Error
2372
Error
2373
Error
2374
Error
2375
Error
2376
Error
2377
Error
2378
Error
2379
Error
2380
Error
2381
Error
218
Possible cause
Stepper card X50
overcurrent
Stepper card X50 watchdog
(Foot lifting)
Stepper card X50 motor
overload/overvoltage/over-
current (Foot stroke)
Stepper card X50 sewing
motor encoder not con-
nected (Foot stroke)
Stepper card X50 sewing
motor encoder not initialized
(Foot stroke)
Stepper card X50 init position
not found (Foot stroke)
Stepper card X50 not
enabled (Foot stroke)
Stepper card X50 overload
(Foot stroke)
Stepper card X50 encoder
failure (Foot stroke)
Stepper card X50 Current
sensor failure (Foot stroke)
Stepper card X50 Incorrect
stepping motor direction of
rotation (Foot stroke)
Stepper card X50 reference
drive failure (Foot stroke)
Corrective
• Check for stiff movement
• Perform software update
• Check selection of class
• Check selection of class
• Replace the control
• Replace encoder
• Replace stepper motor
• Replace the control
• Perform software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace encoder
• Replace the control
• Replace encoder
• Check if plugs have been mixed up
• Check the wiring in the machine distribu-
tor and change it if necessary
• Check for stiff movement
• Replace encoder
• Replace motor
Operating Instructions D887 e-con - 00.0 - 11/2023