Code
Type
9352
Error
9353
Information Needle thread tension sen-
9354
Error
9360
Error
9361
Error
9362
Error
9370
Warning
9371
Warning
9372
Warning
9910
Warning
9911
Warning
9912
Warning
9913
Warning
9914
Warning
9915
Warning
234
Possible cause
Right thread tension pcb is
not connected
sor pcb not connected
Needle Transport PCB not
connected
Edge guide pcb is not
connected
Edge guide x-axis pcb is not
connected
Edge guide y-axis pcb is not
connected
Scanner module not
connected
Scanner module 24 V Error
Scanner module 5 V Error
Sewing stop
Power down
Restart necessary
Empty bobbin
Reset
Please Wait!
Corrective
• Check connection cables
• Perform software update
• Replace PCB
• Check connection cables
• Perform software update
• Replace thread tension sensor
• Check connection cables
• Perform software update
• Replace needle transport PCB
• Check connection cables
• Perform software update
• Replace PCB
• Check connection cables
• Perform software update
• Replace PCB
• Check connection cables
• Perform software update
• Replace PCB
• Check connection cables
• Perform software update
• Replace scanner module
• Check connection cables
• Check connected scanners
• Replace scanner module
• Stored analogue value for stroke
• Check tilt sensor on machine
• Check 24V
• Replace the control
• The control is switched off
• Switch off the control
• Please insert a full bobbin
• Remove USB key!
• Please wait and do not remove USB key