Troubleshooting
Code
Type
9951
Warning
9953
Warning
9954
Warning
9955
Warning
9956
Warning
9957
Warning
9958
Warning
9961
Warning
9962
Warning
9963
Warning
9964
Warning
Operating Instructions D887 e-con - 00.0 - 11/2023
Possible cause
Please press Service stop
Desk is positioning
Desk height error
Desk positioning Timeout
Desk Height Sensor Error
Height limit control active
A function of the Perfect
Quality Sensor (PQS) is
active
Material thickness above
maximum limit
Material thickness below
minimum limit
Please Wait!
Edge Guide in Wrong
Position
Corrective
• Please press the Service stop button to
activate it
Caution!
Height of the desk is being adjusted. Pay
attention to tabletop and surrounding area!
• Tap the touch area to stop!
The desk height measurement produced an
implausible value. Check the measurement
range for interfering objects and keep the
area clear while performing the movement.
Reset height?
• "Yes" for resetting to the current value
• "No" for keeping the old value
• A timeout occurred during positioning.
• If the desk is not positioned at its minimum
or maximum height, check if it is blocked
The sensor for the desk height measurement
is not responding or transmits a faulty signal.
The height adjustment is not possible.
• Check cable connections
• Check if the sensor is switched on
• The height cannot be adjusted until the
error has been corrected and the
machine has restarted
• Height limit control active
• A function of the Perfect Quality Sensor
(PQS) is active. Therefore the lifting
height or the needle position could
change automatically.
• The current material thickness exceeds
the maximum permissible limit.
• The current material thickness falls below
the maximum permissible limit.
• Please wait for the ongoing operation to
be finished
• Edge Guide must be in the right position
237