Dürkopp Adler D887 e-con Operating Instructions Manual page 215

Table of Contents

Advertisement

Troubleshooting
Code
Type
1120
Error
1121
Error
1203
Error
1204
Information Position not reached
1205
Information Position not reached
1206
Information Position not reached
1207
Information Position not reached
1302
Error
Operating Instructions D887 e-con - 00.0 - 11/2023
Possible cause
Sewing motor initialization
failure
Sewing motor watchdog
Position not reached (during
thread cutting, reversal, etc.)
(during bartack)
(during bartack)
(during bartack)
(during bartack)
Failure with sewing motor
current
Corrective
• Perform software update
• Check selection of class
• Perform software update
• Check selection of class
• Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
• Check position thread lever at top dead
center
• Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
• Check position thread lever at top dead
center
• Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
• Check position thread lever at top dead
center
• Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
• Check position thread lever at top dead
center
• Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
• Check position thread lever at top dead
center
• Check Service Stop
• Check for stiff movement
• Replace encoder
• Replace motor