Dürkopp Adler D887 e-con Operating Instructions Manual page 216

Table of Contents

Advertisement

Code
Type
1330
Error
2101
Error
2105
Error
2121
Error
2122
Error
2130
Error
2131
Error
2152
Error
2171
Error
2172
Error
2173
Error
2174
Error
2175
Error
2176
Error
214
Possible cause
No response from sewing
motor
Stepper card X30 reference
drive timeout
Stepper card X30 blockage
Stepper card X30 encoder
plug (Sub-D, 9-pin) not
connected
Stepper card X30 flywheel
position not found
Stepper card X30 not
responding
Stepper card X30
initialization failure
Stepper card X30
overcurrent
Stepper card X30 watchdog
(Stitch length)
Stepper card X30 motor
overload / overvoltage /over-
current (Stitch length)
Stepper card X30 sewing
motor encoder not connected
(Stitch length)
Stepper card X30 sewing
motor encoder not initialized
(Stitch length)
Stepper card X30 init position
not found (Stitch length)
Stepper card X30 not
enabled (Stitch length)
Corrective
• Perform software update
• Replace the control
• Check reference sensor
• Check for stiff movement
• Connect encoder cable to the control, use
correct connection
• Check stepper motor 1 for stiff movement
• Perform software update
• Replace the control
• Perform software update
• Check selection of class
• Check for stiff movement
• Perform software update
• Check selection of class
• Check selection of class
• Replace the control
• Replace encoder
• Replace stepper motor
• Replace the control
• Perform software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
Operating Instructions D887 e-con - 00.0 - 11/2023