Code
Type
2579
Error
2580
Error
2581
Error
2583
Error
2584
Error
2585
Error
2587
Error
2588
Error
2601
Error
2605
Error
2621
Error
2622
Error
2630
Error
222
Possible cause
Stepper card X70 Current
sensor failure (Upper puller)
Stepper card X70 Incorrect
stepping motor direction of
rotation (Upper Puller)
Stepper card X70 reference
drive failure (Upper puller)
Stepper card X70 overcurrent
(Upper puller)
Stepper card X70 parameter
initialization (Upper puller)
Stepper card X70 insulation
error (Upper puller)
Stepper card X70 transport
interval failure (Upper puller)
Stepper card X70 reference
drive failure (Upper puller)
Stepper card X80 reference
run timeout (Bottom puller)
Stepper card X80 stepper
motor blockage (Bottom
puller)
Stepper card X82 encoder
plug (Sub-D, 9-pin) not
connected (Bottom puller)
Stepper card X80 flywheel
position not found (Bottom
puller)
Stepper card X80 not
responding (Bottom puller)
Corrective
• Replace the control
• Replace encoder
• Check if plugs have been mixed up
• Check the wiring in the machine distribu-
tor and change it if necessary
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
• Perform software update
• Check selection of class
• Check motor phase and PE for low-
impedance connection
• Replace encoder
• Replace sewing motor
• Perform software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Check reference sensor
• Check for stiff movement
• Connect encoder cable to the control,
use correct connection
• Check stepper motor 6 for stiff movement
• Perform software update
• Replace the control