Troubleshooting
Code
Type
2631
Error
2671
Error
2672
Error
2673
Error
2674
Error
2675
Error
2676
Error
2677
Error
2678
Error
2679
Error
2680
Error
2681
Error
2683
Error
Operating Instructions D887 e-con - 00.0 - 11/2023
Possible cause
Stepper card X80 initializa-
tion failure (Bottom puller)
Stepper card X80 watchdog
(Bottom puller)
Stepper card X80 motor
overload/overvoltage/over-
current (Bottom puller)
Stepper card X80 sewing
motor encoder not connected
(Bottom puller)
Stepper card X80 sewing
motor encoder not initialized
(Bottom puller)
Stepper card X80 init
position not found
(Bottom puller)
Stepper card X80 not
enabled (Bottom puller)
Stepper card X80 I²t
(Bottom puller)
Stepper card X80 encoder
failure (Bottom puller)
Stepper card X80 Current
sensor failure (Bottom puller)
Stepper card X80 Incorrect
stepping motor direction of
rotation (Bottom puller)
Stepper card X80 reference
drive failure (Bottom puller)
Stepper card X80 overcurrent
(Bottom puller)
Corrective
• Perform software update
• Check selection of class
• Perform software update
• Check selection of class
• Check selection of class
• Replace the control
• Replace encoder
• Replace stepper motor
• Replace the control
• Perform software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace encoder
• Replace the control
• Replace encoder
• Check if plugs have been mixed up
• Check the wiring in the machine distribu-
tor and change it if necessary
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control