Dürkopp Adler D887 e-con Operating Instructions Manual page 111

Table of Contents

Advertisement

Programming Commander DELTA
Operating Instructions D887 e-con - 00.0 - 11/2023
Setting options Sewing foot pressure
Menu item
Setting 1
Linear
Sewing foot pressure
Value range
absolute
00 – 20
Min. Material thickness
Value range
00.0 – 10.0 [mm]
Max. Material thickness
Value range
00.0 – 10.0 [mm]
Linear
Offset
Value range -20 – 20
with
offset
Min. material thickness
Value range
00.0 – 10.0 [mm]
Max. material thickness
Value range
00.0 – 10.0 [mm]
Setting 2
Maximum sewing foot
pressure reached at the
upper material thickness
limit.
Material thickness at which
the adaption in sewing foot
pressure should start.
Material thickness up to
which the adaption in
sewing foot pressure
should occur.
Difference up to maximum
sewing foot pressure
reached at the upper
material thickness limit.
Material thickness at which
the increase in sewing foot
pressure should start.
Material thickness up to
which the increase in
sewing foot pressure
should occur.
109