200
Fig. 111: Establishing equipotential bonding
(1) - Control connection
(2) - Motor ground cable
To establish equipotential bonding:
1.
Connect the ground cable to the port on the switch box (1).
2.
Feed the ground cable through the hole in the tabletop.
3.
Connect the ground cable to the port on the machine head (4).
Important
To establish equipotential bonding, you need to assemble
the necessary components to the connection on the control in
the following order: Locking washer, ground cable of the machine
head (3), ground cable of the motor (2), washer, nut.
(3) - Ground cable for
the machine head
(4) - Connection to
the machine head
Operating Instructions D887 e-con - 00.0 - 11/2023