Troubleshooting
Code
Type
8166
Error
8170
Error
8171
Error
8172
Error
8173
Error
8174
Error
8175
Error
8176
Error
8177
Error
8178
Error
8179
Error
8180
Error
8181
Error
8182
Error
Operating Instructions D887 e-con - 00.0 - 11/2023
Possible cause
Stepper Puller Bottom revo-
lution speed
Stepper Puller Bottom
watchdog
Stepper Puller Bottom motor
overload/overvoltage/
overcurrent
Stepper Puller Bottom sewing
motor encoder not connected
Stepper Puller Bottom sewing
motor encoder not initialized
Stepper Puller Bottom init
position not found
Stepper Puller Bottom not
enabled
Stepper Puller Bottom
overload
Stepper Puller Bottom
encoder failure
Stepper Puller Bottom
Current sensor failure
Stepper Puller Bottom
Incorrect stepping motor
direction of rotation
Stepper Puller Bottom refer-
ence drive failure
Stepper Puller Bottom
overcurrent
Stepper Puller Bottom
parameter initialization
Corrective
• Speed of the Stepper Puller Bottom
• Perform software update
• Check selection of class
• Check selection of class
• Replace the control
• Replace encoder
• Replace stepper motor
• Replace the control
• Perform software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
• Check for stiff movement
• Replace encoder
• Replace motor
• Connect encoder cable to the control:
Use correct connection
• Replace the control
• Replace encoder
• Check if plugs have been mixed up
• Check the wiring in the machine distribu-
tor and change it if necessary
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
• Perform software update
• Check selection of class