Dürkopp Adler D887 e-con Operating Instructions Manual page 227

Table of Contents

Advertisement

Troubleshooting
Code
Type
3110
Information Right thread tension magnet
3111
Information Left thread tension magnet
3112
Information Reference failure (right)
3113
Information Reference failure left thread
3150
Information Maintenance required
3161
Information Bobbin winder over
3210
Information Needle thread monitor (right) • Check the needle thread (right).
3211
Information Bobbin thread is broken
3212
Information Needle thread monitor (right) • Check the needle thread (left).
3223
Information No loop (right)
3224
Information Bobbin Rotation Monitor
3225
Information SSD sensor is soiled
3226
Information No loop (left)
Operating Instructions D887 e-con - 00.0 - 11/2023
Possible cause
is not connected
is not connected
thread tension
tension
temperature
Corrective
• Check the connection of right thread
tension magnet
• Check the connection of left thread
tension magnet
• Restart the machine
• Restart the machine
• For information on maintenance of the
machine, see the service instructions for
the machine
• The bobbin winder was running too long.
The bobbin winder is deactivated for
30 minutes.
• Check the bobbin thread
Skip stitch monitor
• The sensor of the skip stitch monitor
detected during the sewing process that
the loop of the needle thread was not
taken up, resulting in a "skip stitch".
• The bobbin is not rotating
• Check the bobbin, advance the initial
thread
• Use compressed air or a soft cotton cloth
to clean the sensor
Skip stitch monitor
• The sensor of the skip stitch monitor
detected during the sewing process that
the loop of the needle thread was not
taken up, resulting in a "skip stitch".
225

Advertisement

Table of Contents
loading

Table of Contents