Code
Type
9965
Warning
9966
Warning
9967
Warning
9968
Warning
9969
Warning
9970
Warning
9971
Warning
9972
Warning
9973
Warning
9974
Warning
9975
Warning
9976
Information Daily piece counter reached • Daily piece counter reached
9977
Warning
9978
Information • Poka Yoke Function 1
238
Possible cause
Select target position
Thread Tension too low
(Warning)
Edge Guide in Wrong
Position
PQS not connected
Thread Tension too high
(Warning)
The limit values of the thread
tension have been exceeded
too often!
The thread tension value
does not change. The thread
may be broken or the connec-
tion to the sensor is lost.
Scan required
Another scan required
Scan again as RFID tags did
not match
Scan canceled
Switch off collision
protection
Corrective
• Select target position
• Thread Tension too low (Warning)
• Edge Guide must be in the right position
• PQS is activated but not connected,
please check the connection to the PCB
or call the DA service
• Thread Tension too high (Warning)
• The limit values of the thread tension
have been exceeded too often!
• The thread tension value does not
change. The thread may be broken or the
connection to the sensor is lost.
• Please scan the RFID tag
• Please scan the same RFID tag again
• Please scan the same RFID tag as before
• Please scan the same RFID tag again
• Attention: The electronic edge guide is
protected by safety zones to prevent colli-
sions. By activating this function, you are
switching off this collision protection.
There is an increased risk of the edge
guide colliding with other components of
the machine.
The system is waiting for a release of Poka
Yoke Function 1.