Dürkopp Adler D887 e-con Operating Instructions Manual page 230

Table of Contents

Advertisement

Code
Type
6362
Information No valid data on internal
6363
Information No valid data on internal and
6364
Information No valid data on internal
6365
Information Internal EEprom defective
6366
Information Internal EEprom defective
6367
Information Internal EEprom defective
7270
Information External CAN
7800
Information DACFlex not connected
8101
Error
8104
Error
8106
Error
228
Possible cause
EEprom (internal data struc-
tures are not compatible with
the external data storage
device)
external EEprom (software
version is not compatible
with the internal data storage
device, emergency operat-
ing features only)
EEprom and no external
EEprom connected
(the internal data structures
are not compatible with the
external data storage
device)
and external data not valid
(emergency operating
features only)
and external data not valid
(emergency operating
features only)
Stepper Puller Top reference
drive timeout
Stepper Puller Top stepper
motor blockage
Stepper Puller Top encoder
plug not connected
Corrective
• Check machine ID connection
• Switch off the control, wait until the LEDs
have gone out, and then switch on the
control again
• Software update
• Check machine ID connection
• Switch off the control, wait until the LEDs
have gone out, and then switch on the
control again
• Software update
• Check machine ID connection
• Switch off the control, wait until the LEDs
have gone out, and then switch on the
control again
• Software update
• Replace the control
• Replace the control
• Replace the control
• Check connection cables
• Perform software update
• Replace CAN slaves
• Check DACFlex connection
• Check reference sensor
• Check for stiff movement
• Connect encoder cable to the control
• Use correct connection
Operating Instructions D887 e-con - 00.0 - 11/2023
Troubleshooting

Advertisement

Table of Contents
loading

Table of Contents