CounterAndTimerControl

Configure counter settings.
Note: This camera only supports the counter functions.
Related Topic:
Counter and Timer Control Function
Counter and Timer Control
Item
CounterSelector
CounterEventSource
CounterEventActivation
CounterReset
CounterValue
CounterStatus
Setting
Default
Range
Value
0: Counter0
1: Counter1
0: Counter0
2: Counter2
3: Counter3
-
0: Off
1:Rising
Edge
-
2:Falling
Edge
-
-
0~ 32bit max 0
0:
-
CounterIdle
User Manual (Ver. Tentative) - Setting List
Select the counter.
Assign the Counter Event signal for which you want to read the count
value to a dedicated counter, and read the value.
0: Off
1: FrameTrigger (Counter0 only)
2: Exposure Start (Counter1 only)
3: Sensor Readout (Counter2 only)
4: FrameTransferEnd (Counter3 only)
Set the count timing. The setting value is fixed with the following data.
Default:
CounterSelector=0, 1, 2: Rising Edge
CounterSelector=3: Falling Edge
Reset the counter.
Display the count value.
Display the counter status.
0: CounterIdle
1: CounterTriggerWait
2: CounterActive
3: CounterCompleted
4: CounterOverflow - Count value exceeded the maximum value