Usage Precautions

Notes on Cable Configurations

The presence of lighting equipment and television receivers nearby may result in video noise. In
such cases, change the cable configurations or placement.

Notes on Attaching the Lens

How to Clean a Sensor
Avoiding Dust Particles
When attaching the lens to the camera, stray dust and other particles may adhere to the sensor
surface and rear surface of the lens. Be careful of the following when attaching the lens.
Work in a clean environment.
l
Do not remove the caps from the camera and lens until immediately before you attach the
l
lens.
To prevent dust from adhering to surfaces, point the camera and lens downward and do not
l
allow the lens surface to come into contact with your hands or other objects.
Always use a blower brush to remove any dust that adheres.
l
Never use your hands or cloth, blow with your mouth, or use other methods to remove dust.
l

Notes on LAN Cable Connection

Secure the locking screws on the connector manually, and do not
use a driver. Do not secure the screws too tightly. Doing so may
wear down the screw threads on the camera. (Tightening torque:
0.147 Nm or less)
Caution:
Secure manually. Do not secure too tightly.

Notes on SFP+ Module Installation

Check the operation manual of the SFP+ module to be used, and attach it or remove it from the
camera. The SFP module can be attached to and removed from the camera only when the
camera is turned off.
Many SFP modules and fiber optic cables are Class 1 laser products. Do not look into connectors
and cables when installing or removing. There is a risk of injury to eyes.