4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. Do one of the following:
a. Remove the air baffle .
b. Remove the midplane drive cage .
9. Remove the energy pack holder:
a. Pull and hold the release latch on the holder (callout 1).
b. Pull the holder towards the front panel to disengage from chassis (callout 2).
Results
Results
To replace the component, reverse the removal procedure.
Removing and replacing the energy pack
Removing and replacing the energy pack
Procedure
Procedure
1. Power down the server.
2. If installed, open the cable management arm.