HPE ProLiant DL345 Gen11 Service And Maintenance Manual page 86

Table of Contents

Advertisement

Results
Results
To replace the component, reverse the removal procedure.
Removing and replacing a fan
Removing and replacing a fan
About this task
About this task
CAUTION: To maintain proper system cooling, do not operate the server for long period with the access panel open or
CAUTION:
removed. Operating the server in this manner results in an improper system airflow. For internal hot-plug component
procedures, complete the procedure within 60 seconds. Failure to do so can cause the system temperature to increase and
trip the safety threshold. When this happens:
The health LED flashes amber.
The operating system gracefully shuts down.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with
CAUTION:
either a component or a blank.
IMPORTANT:
IMPORTANT:
The fan setup can either be standard, single-rotor fans or high-performance, dual-rotor fans. Do not mix fan types in the
same server.
Procedure
Procedure
1. If installed, open the cable management arm.
HPE ProLiant DL345 Gen11 Server Service and Maintenance Guide