HPE ProLiant DL345 Gen11 Service And Maintenance Manual page 44

Table of Contents

Advertisement

IMPORTANT:
IMPORTANT:
When the server is in standby mode, auxiliary power is still being provided to the system.
To power down the server, use one of the following methods:
Press and release the Power On/Standby button.
This method activates a controlled shutdown of applications and the OS before the server enters standby mode. It can also activate a
shutdown behavior governed by an OS configuration or policy.
Press and hold the Power On/Standby button for more than 4 seconds to force the server to enter standby mode.
This method forces the server to enter standby mode without properly exiting applications and the OS. If an application stops
responding, you can use this method to force a shutdown.
Use a virtual power button selection through iLO 6.
This method initiates a controlled remote shutdown of applications and the OS before the server enters standby mode.
Before proceeding, verify that the server is in standby mode by observing that the system power LED is amber.
Open the cable management arm
Open the cable management arm
Procedure
Procedure
1. Press and hold the blue PUSH
PUSH button on the retention bracket.
2. Swing the arm away from the rear panel.
Extend the server out of the rack
Extend the server out of the rack
Prerequisites
Prerequisites
Before you perform this procedure, review the Rack warnings and cautions.
HPE ProLiant DL345 Gen11 Server Service and Maintenance Guide
44

Advertisement

Table of Contents
loading

Table of Contents