Before you perform this procedure, make sure that you have the following items available:
T-15 Torx screwdriver
T-20 Torx screwdriver
Hex screwdriver
Alcohol wipe
Procedure
Procedure
1. Power down the server.
2. If installed, open the cable management arm.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. Do one of the following:
a. Remove the air baffle .
b. Remove the midplane drive cage .
9. Remove the fan cage.
10. Disconnect all cables from the expansion cards, riser boards, and the system board.
11. Remove all DIMMs.
12. Remove all riser cages