Application "Logical Functions; Application "Internal Rtc - Busch-Jaeger SD/U12.55.11-825 Manual

Hide thumbs Also See for SD/U12.55.11-825:
Table of Contents

Advertisement

7.10.4

Application "Logical functions"

This application (function) has not an own application page. The logic functions can be defined
in channels and run in the background.
The channels / logic functions can be created via the DCA.
1. Open the "Applications" tab in the library area.
2. Click on "Logic functions", a page with a plus appears here.
3. Click on this page, and a channel will be added and displayed in the tree structure.
Notice
Individual logic functions can be created in the respective channels. The
channels can be added via the work area.
For further setting/selection options via the "Parameter" area for the settings of the logic
functions, see chapter 8.17 "Application "Logical functions"" on page 159.
7.10.5

Application "Internal RTC"

The internal room temperature controller (RTC) can be controlled via the "RTC control element"
(extension unit). For this the control element must be allocated accordingly and equipped with
group addresses.
The general settings can be made via the DCA as follows:
1. Open the "Applications" tab in the library area.
2. Open the "Internal RTC".
The general settings for this application are displayed in the "Parameter" area and can
be edited here.
Notice
Individual internal RTCs can be created. These can also be added via the work
area.
For further setting or selection options via the "Parameter" area for the general settings of the
function of the internal RTC, see chapter 8.18 "Application "Internal RTC"" on page 173.
Product manual 2CKA001473B5472
Commissioning of the KNX function via DCA
You can add more channels via the page with the plus.
A maximum of 10 channels can be added.
If such a channel is called up via the tree structure, the settings can be
adjusted for the individual logic functions in the "Parameter" area.
By clicking the arrow next to "Logic functions", all available channels are
displayed in the tree structure.
Here a page with a plus is displayed. This page must be clicked. This is how
a further internal RTC is added and displayed in the tree structure.
If it is called up via the tree structure, the settings can be adjusted for the
individual internal RTCs in the "Parameter" area.
By clicking the arrow next to "Internal RTC", all available internal RTCs are
displayed.
│67