Installing a type-a modular controller option
Installing a type-a modular controller option
CAUTION:
CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
Compatible controller cable option
T-15 Torx screwdriver
Procedure
Procedure
1. If installed, remove the front bezel .
2. Power down the server.
3. If installed, release the cable management arm.
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Disconnect all peripheral cables from the server.
6. Remove the server from the rack .
7. Place the server on a flat, level work surface.
8. Remove the access panel .
9. Install the type-a storage controller:
a. Insert the alignment pins on the system board through the holes on the card (callout 1).
b. Press the area of the card marked as PRESS TO INSTALL to ensure that the card is firmly seated on the slot.
c. Tighten the card thumbscrews.
Installing a type-a modular controller option