8 SFF + 2 SFF drive bay numbering

8 SFF + 2 SFF drive bay numbering
In the SFF drive configuration:
Drives are assigned to box 1 (green) and the optional box 2 (orange).
SAS, SATA, U.2 NVMe, and U.3 NVMe drives are supported.
When a Gen10 Plus tri-mode controller is used together with a U.3 drive backplane, the system will support mixed drive
configuration.
When installing NVMe drives, install either all U.2 or all U.3 drives. Mixed NVMe drive type installation is not supported.
8 SFF SAS/SATA: All box 1 drives connected to the NVMe/SATA port 8A supports SATA software RAID.
8 SFF NVMe: The box 1, drives 1–2 connected to the NVMe port 3A supports NVMe software RAID.
8 SFF SAS/SATA + 2 SFF NVMe:
All box 1 drives connected to the NVMe/SATA port 8A supports SATA software RAID.
All box 2 drives connected to the NVMe port 4A supports NVMe software RAID.
8 SFF NVMe + 2 SFF NVMe:
The box 1, drives 1–2 connected to the NVMe port 3A supports NVMe software RAID.
The box 1, drives 3–8 and the box 2 drives will not support software RAID.
8 SFF + 2 SFF drive bay numbering