Installing The Secondary Riser Option For Half-Height Expansion Cards - HPE ProLiant DL325 Gen10 Plus v2 User Manual

Hide thumbs Also See for ProLiant DL325 Gen10 Plus v2:
Table of Contents

Advertisement

Installing the secondary riser option for half-height expansion cards

Installing the secondary riser option for half-height expansion cards
Procedure
Procedure
1. If installed, remove the front bezel .
2. Power down the server.
3. If installed, release the cable management arm.
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Disconnect all peripheral cables from the server.
6. Remove the server from the rack .
7. Place the server on a flat, level work surface.
8. Remove the access panel .
9. Install the secondary riser cage:
a. Align the arrows on the riser cage with the arrows on the power supply cage (callout 1).
b. Carefully press the riser down on its system board connector (callout 2).
Make sure that the riser board is firmly seated.
c. Simultaneously push and rotate the half-turn spring latch to 180° (callout 3).
d. Close the spring latch (callout 4).
Installing the secondary riser option for half-height expansion cards
137