10. Install the NVMe drive.
11. Install the access panel.
12. Install the server into the rack.
13. Connect all peripheral cables to the server.
14. Connect each power cord to the server.
15. Connect each power cord to the power source.
16. Power up the server.
17. If removed, install the bezel.
The installation is complete.

Storage controller options

This server supports the following storage controllers:
For SATA drives only – Embedded HPE Smart Array S100i SR Gen10 controller
For SAS and SATA drives:
Smart Array type-a modular controller
Smart Array PCIe plug-in controller
In 8SFF NVMe configuration, Smart Array PCIe plug-in controller is not supported.

Installing a Smart Array type-a modular controller

Secondary riser slot 3 is not available when a Smart Array type-a module controller is installed in the system.
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
Smart Array modular controller option
Compatible controller cable option
T-15 Torx screwdriver
If you are installing a Smart Array P-class Gen10 controller, an energy pack option is required.
Before you perform this procedure, perform the following steps:
1. Back up data on the system.
2. Close all applications.
3. Update the server firmware if it is not the latest revision.
4. Do one of the following:
Hardware options installation
61