Syslog Transmission Configuration - Panasonic PN261693D Manual

Table of Contents

Advertisement

3.5.3.

Syslog Transmission Configuration

Press G (command) on the screen of System Security Configuration, and then you
can see Syslog Transmission Configuration Menu as Figure 3-12. You can configure
Syslog servers as the destination of transmitting system-log on this screen.
PNxxxxxx Local Management System
System Security Configuration -> Syslog Transmission Configuration Menu
Status: Disabled
Syslog Server List:
No.
IP Address
----
-------------
1
0.0.0.0
2
0.0.0.0
3
0.0.0.0
4
0.0.0.0
-------------------------------- <COMMAND> -----------------------------------
Set Server [S]tatus
Set Server [F]acility [C]lear Server Information
Command>
Enter the character in square brackets to select option
Figure 3-12: Syslog Transmission Configuration
Screen Description
Status
Displays the status of the configuration of a Syslog server. The factory default
settings is Disable.
Enabled
Disabled
No.
Displays the management number of the Syslog server.
IP Address
Displays an IP address of the Syslog server.
Facillity
Displays the facility value.
The following describes how to use several commands on this screen.
S
Configures the status of Syslog transmission.
1. Press S (command), and then the appearance of the command prompt becomes "Enable
or Disable Server (E/D)>". After that, press E to enable and D to disable it.
F
Configures a facility. The information on a Syslog server with the IP address configured can
change the facility.
1. Press F, and then the appearance of the command prompt becomes "Enter manager
entry number>". After that, enter the number to be configured.
2. The appearance of the command prompt becomes "Enter Server Facility>". Then enter
the value in the range from 0 to 23.
Facility
----------
Facility0
Facility0
Facility0
Facility0
Set Server [I]P
The configuration of the Syslog server is enabled.
The configuration of the Syslog server is disabled.
44
[Q]uit to previous menu