Panasonic PN261693D Manual page 174

Table of Contents

Advertisement

The following describes how to use several commands on this screen.
N
Displays the value of the next port.
 
Press N (command), and then the SFP status of the next port is displayed.
P
Displays the value of the previous port.
 
Press P, and then the SFP status of the previous port is displayed.
S
Configures to enable or disable to outgo SNMP traps during the status change.
 
Press S, and then the appearance of the command prompt becomes "Enable or Disable
Limit trap(E/D)>". Press E to enable and send traps, and D to disable that.
R
Set the threshold of the receiving-light power.
 
Press R, and then the appearance of the command prompt becomes "Auto or Manual
(A/M)>". Press A to use the content, including the configuration of how the SFP is set,
and M to configure manually. After that, the appearance becomes "High or Low(H/
L)>". Press H to set the upper-limit, and L to set the lower limit. After that, the
appearance becomes "Alarm or Warning(A/W)>". Press A to configure an alarm, and
W to configure a warning. After that, the appearance becomes "Enter value>". Then
enter the value.
T
Sets the threshold of the transmitting-light power.
 
 
Press T, and then the appearance of the command prompt becomes "Auto or Manual (A/
M)> ". Press A to use the content, including the configuration of how the SFP is set and M
to configure manually. After that, the appearance becomes "High or Low(H/L)>". Press
H to set the upper-limit and L to set the lower limit. After that, the appearance becomes
"Alarm or Warning(A/W)>". Press A to configure an alarm, and W to configure a warn-
ing. After that, the appearance becomes "Enter value>". Then enter the value.
V
Applies the voltage threshold.
 
 
Press V, and then the appearance of the command prompt becomes "Auto or Manual
(A/M)>". Press A to use the content, including the configuration of how the SFP is set,
and M to configure manually. After that, the appearance becomes "High or Low(H/
L)>". Press H to set the upper-limit and L to set the lower-limit. After that, the
appearance becomes "Alarm or Warning(A/W)>", press A to configure an alarm, and
W to configure a warning. After that, the appearance becomes "Enter value>". Then
enter the value.
E
Sets the threshold of a temperature.
 
Press E, and then the appearance of the command prompt becomes "Auto or Manual (A/
M)>". Press A to use the content, including the configuration of how the SFP is set, and
M to configure manually. After that, the screen shows "High or Low(H/L)>". Press H to set
the upper-limit and L to set the lower-limit. After that, the appearance becomes "Alarm
or Warning(A/W)>", press A to configure an alarm, and W to configure a warning. After
that, the screen shows "Enter value>". Then enter the value.
B
Sets the threshold of a current.
 
Press B, and then the appearance of the command prompt becomes "Auto or Manual
(A/M)>". Press A to use the content, including the configuration of how the SFP is set,
and M to configure manually. After that, the appearance becomes "High or Low(H/L)>".
Press H to set the upper-limit and L to set the lower limit. After that, the screen shows
"Alarm or Warning(A/W)>", press A to configure an alarm, and W to configure a warn-
ing. After that, the screen shows "Enter value>". Then enter the value.
Q
Returns to the top menu.