Panasonic PN261693D Manual page 131

Table of Contents

Advertisement

Screen Description
No.
Displays the port-number.
Admin
Displays if the power supply can be operated.
The factory default settings is "Up".
Up
Down
Status
Displays the status of power supply.
Pwr
NotPwr
Over
Layer
Displays the classification-method compatible with the terminal equipment.
1
2
Class
Displays Class detected by the classification.
Prio.
Displays the priority of the power supply.  
Crit.
High
Low
Limit
Displays the upper-limit of the power supply (200mW: unit). The factory default
settings is "Auto".
Pow.
Displays the power supply (100mw: unit).
Vol.
Displays the voltage value (1V: unit).
Cur.
Displays the current value (1mA: unit).
Indicates that power supply is possible.
Indicates that power supply is impossible.
Indicates that PoE power-supply is operated.
Indicates that PoE power-supply is not operated.
Indicates that operating the power supply stops because of the
requirement for the power supply exceeding the upper-limit of the
power supply (amount).
Indicates that the power supply is operated in accordance with the
Physical Layer Classification.
Indicates that the power supply is operated in accordance with the
Data Link Lalyer Classification.
Indicates that this task is to be performed as the highest priority.
Indicates that this task is performed as the lower priority than Crit.
Indicates that low is not a priority.
131

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga-ml series

Table of Contents