Charger TRIP is occurred after abnormality lamp is on.
After opening the cover which is located on the front bottom side of the charger.
In case error code is "O.C"
current.
Restart the charger as pushing
reset switch in the monitor.
After RESET, request
After-Service if it is not correct
Output over current, established as 110~120% of the rated
Measure
the output current
by DC current measure
15-20A/
100AH
YES
Re-establish charge current
volume (AMP) on the center
side of PCB as turning it anti
clockwise rotation
De-
crease
7-113
Check contact error or breaking of wiring
NO
for current connection the right side of the
PCB(Clean, connection of wiring)
Measure
the output current
by DC current
measure
YES
OK
In-
crease
De-
In-
crease
crease
NO
Change
PCB