Set option
HOUR COUNTER
EVP TYPE
BATTERY CHECK
STOP ON RAMP
SET MOT.TEMPERAT
AUX OUTPUT #1
AUX OUTPUT #2
This option specifies the hour counter mode. It can be set one of two :
- RUNNING : The counter registers travel time only
- KEY ON : The counter registers when the ""key"" switch is closed
Analog/digital : defines the type of the EVP1 electro valve, current controlled :
Analog : the related output manages a proportional valve, current controlled
Digital : the related output manages an on/off valve
This option specifies the handling of the low battery charge detection.
There are three levels :
- Level 0 : Nothing happens, the battery charge level is calculated but is ignored, it
means no action is taken when the battery is discharged.
- Level 1 : BATTERY LOW alarm is raised when the battery level is calculated being
less than or equal to 10% of the full charge.
The BATTERY LOW alarm inhibits the Lifting function.
- Level 2 : BATTERY LOW alarm is raised when the battery level is calculated being
less than or equal to 10% of the full charge.
The BATTERY LOW alarm reduces the maximum truck speed down to
24% of the full truck speed and it inhibits the Lifting function.
Only when the encoder is present, it is possible to electrically hold the truck on a
slope when the accelerator is released but the tiller is not released.
- ON : The stop on ramp feature (truck electrically hold on a ramp) is managed for a
time established by AUXILIARY TIME parameter.
- OFF : The stop on ramp feature is not performed.
That means the truck comes down slowly during the AUXILIARY TIME.
It can be set :
- ANALOG : An analogue sensor for the control of the motor temperature is
connected to CNA#22. Typically the temperature sensor is a PTC
(positive thermal coefficient resistance), providing the sensor
characteristic to Zapi the correct table can be loaded in the controller
software.
1. DIGITAL : A digital (on/off) sensor for the motor temperature monitoring is
connected to CNA#22 input.
2. NONE : No temperature sensor is connected.
PRESENT/ABSENT : When is set PRESENT the ON/OFF valve #1 is used for
platform lift.
If is set ABSENT the ON/OFF valve #1 isn't used.
PRESENT/ABSENT : When is set PRESENT the ON/OFF valve #2 is used for
auxility lift.
If is set ABSENT the ON/OFF valve #2 isn't used. (Not
applicable)
Description
7-33