5)
DESCRIPTION OF PROGRAMMABLE FUNCTIONS
(1)
Menu set model
Connect to
Using CANBUS link, every module connected to can net can act as the "access node" to the
canbus net for the external world.
For example the ZAPI hand console (or the PC-Win console) can be physically connected to one
module and, by the canbus, virtually connected to any other module of the net.
This parameter is used to select the module to which the user wishes to be connected.
Following the numbers associated to each module in Zapi canbus system are showed.
Number associated in canbus net
(2)
M
M
enu set options
Power selector
It sets the truck performances.
OPTION #1 : H (High performance)
OPTION #2 : N (Normal performance)
OPTION #3 : E (Economic performance)
Hour counter
It sets the hour counter displayed.
OPTION #1 : The key hour meter is displayed
OPTION #2 : The traction hour meter is displayed
OPTION #3 : The pump hour meter is displayed
Auxiliary output #1
The options are :
PRESENT : An external load is connected between PAUX and NAUX.
The related diagnosis are enabled.
ABSENT : No external load is connected between PAUX and NAUX.
The related diagnosis are disabled.
Auxiliary voltage #1
It specifies the percentage of battery voltage supplied to AUX coil to close the AUXILIARY electro
valve. This parameter can be changed in the range 0% to 100%.
Speed unit
It sets the speed unit.
OPTION #1 : The speed unit is km/h
OPTION #2 : The speed unit is mph
User password
The options are :
ON : After key-on a user password is asked to utilize the Graphic Smart Display
OFF : No user password needed
02
06
05
09
16
7-55
Module
TRACTION
EPS
PUMP
MHYRIO
GRAPHIC SMART DISPLAY

Advertisement

loading

This manual is also suitable for:

13bop-7