Download Print this page

Hyundai 10BOP-7 Operation Manual page 164

Advertisement

Parameter change
AUX FUNCTION 3
CUTBACK SPEED 4
AUX FUNCTION 4
TURTLE SPEED
MAX ANGLE SP CTB
FREQUENCY CREEP
MAXIMUM CURRENT
ACC SMOOTH
INV SMOOTH
STOP SMOOTH
BRK SMOOTH
STOP BRK SMOOTH
AUXILIARY TIME
MIN EVP
MAX EVP
MAX EVP RED
EVP OPEN DELAY
EVP CLOSE DELAY
CHAT TIME DELAY
DEADMAN DELAY
Hz. It determines the maximum speed when truck steer angle is over MAX ANGLE
SP CTB and lift height is 1500 to 3000mm.
Hz. It determines the maximum speed when truck steer angle is in 10 degrees and
lift height is 5500 to END mm.
Hz. It determines the maximum speed when truck steer angle is over MAX ANGLE
SP CTB and lift height is 5500 to END mm.
Hz. It determines the maximum speed when turtle mode is activated.
Degrees. It determines the angle for speed reduction.
Hz value. This is the minimum speed applied when the forward or reverse switch is
closed, but the accelerator is at its minimum
Maximum level of the current (percentage of the maximum current of the controller).
It gives a parabolic form to the acceleration ramp.
It gives a parabolic form to the acceleration ramp after a direction inversion
Hz. It sets the level of frequency where the smooth effect of the acceleration
parabolic form ends.
It gives a parabolic form to the deceleration ramp.
Hz. It sets the level of frequency where the smooth effect of the deceleration
parabolic form ends.
Time units value (seconds). For the encoder version, it determines the time duration
the truck is hold on the ramp if the STOP ON RAMP option is ON.
0 to 100. This parameter determines the minimum voltage applied on the EVP1
when the position of the lowering lever is at the minimum.
This parameter is not effective if the EVP1 is programmed like a On/Off valve
0 to 100. This parameter determines the maximum voltage applied on the EVP1
when the position of the lowering lever is at the maximum.
If the EVP1 is programmed like a On/Off valve this parameter determines the fixed
voltage applied on the electro valve coil.
0 to 100. This parameter determines the maximum voltage applied on the EVP1
when the position of the lowering lever is at the maximum and lift height is 0 to
600mm. If the EVP1 is programmed like a On/Off valve this parameter determines
the fixed voltage applied on the electro valve coil.
In seconds. It defines the opening ramp of the EVP1 electro valve when related
output is set as Analog (refer to Set Option menu).
In seconds. It defines the closing ramp of the EVP1 electro valve when related
output is set as Analog (refer to Set Option menu).
In seconds. When truck is key on, if the operator doesn't use the truck for the
time(CHAT TIME DELAY), main contactor is open to save energy.
In seconds. Even though the operator step on the deadman switch, It is sometimes
open because of vibration or other things. "DEAD MAN DELAY" is the time dead
man switch signal is being kept "ON" status for set time, even though it is open.
Description
7-32

Advertisement

loading

This manual is also suitable for:

13bop-7