(2)
Pump inverter
Parameter change
ACCELER. DELAY
DECELER. DELAY
DEC DEL LIFT LIM
MAX SPEED UP
MAX SP. UP FORK
MIN SPEED UP
CUTBACK SPEED
LIFT SPEED #1
LIFT SPEED #2
LIFT SPEED #3
LIFT SPEED #4
MAXIMUM CURRENT
Set option
HOUR COUNTER
SET TEMPERATURE
HOUR METER TRUCK
FORK
D.M. PUMP
Level 0 ~ 9 ; It determines the acceleration ramp.
Level 0 ~ 9 ; It determines the deceleration ramp.
Level 0 ~ 9 ; It determines the deceleration ramp. When lift limit function is activated.
It determines the maximum lifting speed with a potentiometer control
It determines the maximum auxility lifting speed with a potentiometer control
It determines the minimum lifting speed with a potentiometer control when the lifting
enable switch is closed.
Hz. It determines the maximum lift speed when lift height is END-100 to END mm.
Hz. It determines the maximum lift speed when lift height is 0 to 1500 mm.
Hz. It determines the maximum lift speed when lift height is 1500 to 3000 mm.
Hz. It determines the maximum lift speed when lift height is 3000 to 5500 mm.
Hz. It determines the maximum lift speed when lift height is 5500 to END-100 mm.
This parameter changes the maximum current of the inverter
This option specifies the hour counter mode. It can be set one of two :
- RUNNING : The counter registers travel time only
- KEY ON : The counter registers when the "key" switch is closed
- ANALOG : An analogue motor thermal sensor is connected between A22 and A23
inputs (the curve can be customized on a customer request).
- DIGITAL : A digital (ON/OFF) motor thermal sensor is connected between A22 and
A23 inputs.
- NONE : No motor thermal sensor switch is connected.
With this parameter set to ON alarms are saved into logbook with truck hourmeter
timestamp instead of pump inverter hourmeter
- OFF : Auxility lift function is not used.
- ON : Auxility lift function is used.
- OFF : Lift and lowering function is available after putting on dead man switch.
- ON : Lift and lowering function is available without regard to put on dead man
switch.