(17)
Place mounting flange of the pump back
in the protected jawed vise and alternately
torque the bolts.
Tighten torque : 6~7kgf m
(43.4~50.6lbf ft)
(18)
Remove pump from vise.
(19)
Place a small amount of clean oil in the
inlet of the pump and rotate the drive shaft
away from the inlet one revolution. If the
drive shaft binds, disassemble the pump
and check for assembly problems, then
reassemble the pump.
6-21