(3)
EPS inverter (AC0)
No. of Pin
Function
A1
NA
A2
SW 2
A3
SW 1
A4
-BATT.
A5
SAFETY
A6
CAN L
A7
KEY
A8
QL
A9
DL
A10
GND
A11
GND
A12
GND
A13
GND
A14
CANH
B1
NA
B2
NA
B3
THMOT
B4
VDC
B5
NA
B6
NA
B7
CHB
B8
CHA
-
2nd toggle switch (90 degrees)
1st toggle switch (0 degrees)
Safety switch lower voltage point
Safety switch higher voltage point
Can bus low
Key in
Stepper motor Q line
Stepper motor D line
GND. encoder D line negative supply
GND. encoder Q line negative supply and EPS motor encoder negative
GND. SW 1 & SW 2 negative
GND. motor thermal sensor negative
Can bus high
-
-
Motor thermal sensor (KTY84-130) input
Encoder positive supply
-
-
Encoder channel B
Encoder channel A