Adjustments
SET BATTERY TYPE
ADJUST BATTERY
THROTTLE 0 ZONE
THROTTLE X POINT
THROTTLE Y POINT
AUX OUTPUT VOLT
AUX OUTPUT V RID
ADJUSTMENT #04
MOTOR SHUTDOWN
IMAX PROTECTION
VACC MAX
VACC NEUTRAL
VACC MIN
VACC MAX FORK
VACC NEUTRAL FRK
VACC MIN FORK
Selects the nominal battery voltage.
Fine adjustment of the battery voltage measured by the controller.
It establishes a dead band in the lift potentiometer input curve.
This parameter, together with the THROTTLE Y POINT, changes the characteristic
of the lift potentiometer input curve : when the potentiometer is depressed to X point
per cent, the corresponding pump speed is Y point percent of the Maximum pump
speed. The relationship between the lift potentiometer position and the pump speed
is linear between the THROTTLE 0 ZONE and the X point and also between the X
point and the maximum potentiometer position but with two different slopes.
This parameter, together with the THROTTLE X POINT, changes the characteristic
of the lift potentiometer input curve : when the potentiometer is de-pressed to X point
per cent, the corresponding pump speed is Y point per cent of the Maximum pump
speed. The relationship between the potentiometer position and the pump speed is
linear between the THROTTLE 0 ZONE and the X point and also between the X
point and the maximum accelerator position but with two different slope.
It specifies the percentage of battery voltage supplied to back buzzer relay coil to
apply the back buzzer.
It specifies the percentage of AUX OUT VOLT parameter, supplied to back buzzer
relay coil to keep back buzzer applied.
This parameter determines the motor temperature level at which the "Motor
temperature" alarm is signalled. The range is from 70
This parameter must be adjusted only if the "Set temperature" (menu "Set option")
parameter is programmed "Analog".
This parameter determines the motor temperature level at which the motor is
shutdown. The range is from 70 C to 160 C with 10 C steps. This parameter must
be adjusted only if the "Set temperature" (menu "Set option") parameter is
programmed "Analog".
%, The maximum current of the inverter.
It is the voltage level, when lift lever is activated in upward direction.
It is the voltage level, when lift lever is not in activation
It is the voltage level, when lift lever is activated in downward direction.
It is the voltage level, when auxility lift lever is activated in upward direction.
It is the voltage level, when auxility lift lever is not in activation
It is the voltage level, when auxility lift lever is activated in downward direction.
Description
7-36
C to 160 C with 10 C steps.